WORLDWIDE SHIPPING via DHL | Free Shipping above 200aed in UAE | Free Samples | Exceptional offerings since 2010

R coat 30-36 UAE

AED 39.00


Odor: Slight ethereal or sweet odor Non-flammable: It is generally non-flammable under normal conditions but can decompose under high heat.Compatibility: Compatible with materials such as copper and aluminum.

in stock

Guarantee safe & secure checkout

Description

R coat 30-36, an aqueous solution is applied in conjunction with woven fiber Glass cloth spreading on the outer surface of insulated GI/Al, ducting, and chilled water piping to provide sealing against air and moisture mechanical impact and resistance to scratches for Indoor application, It is invariably, a must on SA ducting in the space above false ceiling through which return air is being drawn and non-conditioned spaces, chilled water piping, etc. in conjunction with a layer of woven fiberglass cloth It acts as cladding to the insulation material against environmentally hazardous like dust rain, moisture acid vapors, mechanical impacts, Chemicals, and Alkalies, etc. for outdoor application In both the indoor and outdoor application the surface should invariably be finished in two layers of R coat 30-36 over the insulation wrapped with woven fiberglass cloth Invariably an excellent water vapor barrier with low water vapor permeance. This system applies to all types of insulation materials. The product is classified as Class 1 in respect of the Surface Spread of Flame as per BS 476 Part 7.

Method Of Application
The insulation surface should be cleaned thoroughly.
Stir its contents well before use to have homogeneous material before use.
Apply a tack coat with a fully dipped brush and spread it evenly over the insulated surface.
Immediately wrap the Glass cloth smoothly on the wet coating Care should be taken such that the cloth is applied in tightened and straightened position without any wrinkles.
Overlap the seams by at least 50 mm, so no air pockets are formed.
Allow the surface to dry completely.
Apply two finish coats. The first coat must be dried completely before the second coat is applied. Allow the second coat to cure (dry) for a minimum of 24 hours at ambient temperature -30 C px.
Keep the container closed when not in use.
In case of special aesthetic appearance and matching architectural requirements, the last two finish coats, one with plain roller followed by laminated surface rollers fully dipped in both cases.
Coverage
On an average of 1.5 m2/Kg/coats (with three coats)

Storage & Shelf Life
Store under cover to protect from direct sunlight Shelf life is up to 12 months for the unopened containers when stored as directed.

Specific Technical Data Sheet
Color: Milky White

Viscosity @ 30°C : 65000 to 75000 cps

Specific Gravity: 1.4

Bonding Time: 30 minutes (at 30°C DBT 60% RH )

Drying Time: Touch dry for 2 hours, Hard dry for 16 hours

Temperature Range: -25 to 112 C

VOC Content (gram/alter): 0.05

Water Permeance: 0.018 perms As per ASTM E -96

UV Resistance: Excellent

Fungi Resistance: Excellent

Reviews

There are no reviews yet.

Be the first to review “R coat 30-36 UAE”

Your email address will not be published. Required fields are marked *

Introduction

FLORON R-22, commonly known as HCFC-22, is a refrigerant gas historically used in air conditioning
and refrigeration systems. However, due to its ozone-depleting properties, its production has been
phased out in many countries under the Montreal Protocol. Most countries now use alternative refrigerants
with lower environmental impact, such as R-410A, R-134A, and others. For those still seeking R-22, here are the
general technical specifications of FLORON R-22:

1. Wide Application Range

  • FLORON R-22 has been widely used in various sectors, including:

    • Residential air conditioning systems

    • Commercial air conditioning units

    • Industrial refrigeration systems

    • Medium and low-temperature cooling systems

    Due to its broad usage, it has remained a popular choice in the HVAC and refrigeration industry for many years.

2. High Cooling Efficiency

  1. FLORON R-22 offers excellent thermodynamic properties that ensure high cooling efficiency.
    This makes it a highly effective refrigerant for air conditioning and refrigeration systems.
    It provides rapid and long-lasting cooling, delivering a stable and comfortable temperature for users.

3. Availability and Versatility

Before being phased out, R-22 was widely available and compatible with many existing systems,
making it a practical choice for technicians and service providers. Its easy application and system
compatibility made it a versatile option.

Specification:

  • Chemical Formula: CHClF₂
  • Molecular Weight: 86.47 g/mol
  • Boiling Point (at 1 atm): -40.8°C (-41.4°F)
  • Freezing Point: -160°C (-256°F)
  • Appearance: Colorless gas (sometimes appears as a liquid in cylinders)
  • Odor: Slight ethereal or sweet odor
  • Non-flammable: Generally non-flammable under normal conditions but can decompose under high heat.
  • Compatibility: Compatible with materials such as copper and aluminum.

Chemical Formula and Molecular Weight:

  • Chemical Formula: CHClF₂ (Chlorodifluoromethane)

  • Molecular Weight: 86.47 g/mol

Physical Properties

  • Boiling Point (at 1 atm): -40.8°C (-41.4°F)

  • Freezing Point: -160°C (-256°F)

  • Appearance: A colorless gas, though it may appear as a liquid when stored in pressurized cylinders.

  • Odor: Possesses a slight ethereal or sweet odor, making it somewhat distinguishable.

Flammability and Stability

  • Non-Flammable: CHClF₂ is generally non-flammable under standard conditions.

  • Thermal Decomposition: While it does not readily catch fire, exposure to high temperatures or open flames can cause decomposition, potentially leading to the formation of hazardous byproducts

Introduction

FLORON R-22, commonly known as HCFC-22, is a refrigerant gas historically used in air conditioning
and refrigeration systems. However, due to its ozone-depleting properties, its production has been
phased out in many countries under the Montreal Protocol. Most countries now use alternative refrigerants
with lower environmental impact, such as R-410A, R-134A, and others. For those still seeking R-22, here are the
general technical specifications of FLORON R-22:

1. Wide Application Range

  • FLORON R-22 has been widely used in various sectors, including:

    • Residential air conditioning systems

    • Commercial air conditioning units

    • Industrial refrigeration systems

    • Medium and low-temperature cooling systems

    Due to its broad usage, it has remained a popular choice in the HVAC and refrigeration industry for many years.

2. High Cooling Efficiency

  1. FLORON R-22 offers excellent thermodynamic properties that ensure high cooling efficiency.
    This makes it a highly effective refrigerant for air conditioning and refrigeration systems.
    It provides rapid and long-lasting cooling, delivering a stable and comfortable temperature for users.

3. Availability and Versatility

Before being phased out, R-22 was widely available and compatible with many existing systems,
making it a practical choice for technicians and service providers. Its easy application and system
compatibility made it a versatile option.

Related Products

Original price was: AED 45.00.Current price is: AED 40.00.